Permissable factors of safety

Permissable factors of safety for dam concrete

Load Combination Stress Location F.S. Compressive F.S. Tensile
Usual General 3.0 3.0
Local 2.4 1.0
Unusual General 2.0 2.0
Local 1.6 1.0
Extreme General 1.1 1.0
Local 1.0 1.0